Methodology: Reflectance Photometer
Analysis Item: Blood Glucose/Uric Acid/Blood Lipid/Blood Pressure
Measurement Unit: g/dL, g/L, mmol/L
Specimen: Fingertip blood, whole blood
(capillary blood and venous whole
blood), serum or plasma
Specimen Volume: Glucose 1 UL / Uric Acid 3 UL / Blood Lipid 35UL
Pollution levels: 2
Power Source: 4*AA batteries
Memory: Each item 500 sets of records
Bluetooth: Bluebooth to Sync Data with Phone or PC
Automatic Shut Off: 4 Minutes after Last Use
Meter Size:
152* 123**48mm(L*W*H )
Meter Net Weight: About 365g
Meter Storage Conditions: (0-55)℃,<90% RH, (50-106)kPa
System Operating Conditions: 10-40°C;≤90% RH; Seal-Level ≤2000M
Meter Warranty Period: 2 Years
Meter Shelf Life: 4 Years
Medical grade accuracy
Data comparsion
Innovative design
Voice announcement
Data Comparsion
Super large screen
Dimension: 178×101×35.3mm
LCD V.A.: 124×76mm
Power source: 4×AA or 5V1A Type-C USB Cable
Cuff size: 22-32/22-42/22-45cm
Medical grade accuracy
BP trend
Innovative design
Voice announcement
Super large screen
Dimension: 178×101×35.3mm
LCD V.A.: 124×76mm
Power source: 4×AA or 5V1A Type-C USB Cable
Cuff size: 22-32/22-42/22-45cm
BP classification indicator
Average of last 3 values
Irregular heartbeat indicator
Voice announcement
Position sensor detection
Dimension: 85×60×23mm
LCD V.A.: 43×46mm
Power source: 2×AAA batteries
Cuff size: 13.5-21.5cm
FDA-approved BGM device made for RPM(Remote Patient Monitoring), works out of the box, with connectivity and flexible IoT control.
Auto coding: Easy and accurate
Test strip ejector: Clean and convenient
Wide HCT range: HCT 20-70%
Cellular connectivity: Covers many major operators such as
AT&T, T-mobile, and Verizon. Unlimited M2M data plan. Built-in security-whitelisted network, only trusted endpoints were allowed.
Advanced accuracy: A recent independent clinical study conducted shows that 100% of all results are within ±15% of the YSI
plasma results, which is fully compliant with current FDA standards. HCT 20-70% / 8 electrodes / 500 results / Auto sync / Rechargeable
battery / Super fast 5-second test / 0.8 μL blood sample / Test strip ejector / 41-113℉
Test strip ejector: The test strip will be returned automatically without contact with human hand needed, clean and hygienic.
Easy diabetes care: Operation / Easy to use for diabetes care, exquisite & portable, simple operation
The 8 electrodes on the test strip work with the meter to deliver highly accurate results. Detailed functions of these electrodes are:
Code calibration (auto-coding)
Checking humidity exposure
Eliminating hematocrit interference
Checking if the sample is sufficient
Eliminating temperature interference
Checking if the sample is blood or control solution
Checking for possible damage of the test strip
Units of Measurement The meter is pre-set to milligrams per deciliter (mg/dL)
Battery Type: Rechargeable, non-serviceable, 800 mAh, 3.7 Volt DC
nominal, lithium polymer battery (5V input charge voltage)
Enzyme: GOD/Glucose Oxidase
Measurement Range: 20-600 mg/dL
Result Calibration: Plasma-equivalent
Sample: Fresh capillary whole blood
Dimensions: 95.5mm x 59.1mm x 20.7mm
Display Size: 47mm x 37.5mm
Weight: Approximately 69g
Automatic Shutoff: 2 minutes after last action
Technology: Electrochemicla Biosensor
Enzyme: Glucose Oxidase (GOD)
Coding: No coding
Wide HCT range: HCT 20-70%
Result Calibration: Plasma-equivalent
Neonates testing
AST(Alternate sites): Forearm, palm
Advanced accuracy: A recent independent clinical study conducted shows that 100% of all results are within ±15% of the YSI
plasma results, which is fully compliant with current FDA standards. HCT 20-70% / 8 electrodes / 500 results / Auto sync / Rechargeable
battery / Super fast 5-second test / 0.8 μL blood sample / 41-113℉
Easy diabetes care: Operation / Easy to use for diabetes care, exquisite & portable, simple operation
The 8 electrodes on the test strip work with the meter to deliver highly accurate results. Detailed functions of these electrodes are:
Code calibration (auto-coding)
Checking humidity exposure
Eliminating hematocrit interference
Checking if the sample is sufficient
Eliminating temperature interference
Checking if the sample is blood or control solution
Checking for possible damage of the test strip
Measurement Unit: Pre-set with either mg/dL or mmol/L, as per the local stanard
Battery: Rechargeable battery with capacity 250mAh, Battery life ~150 tests after fully charged
Test Range: 10~600 mg/dL(0.6~33.3mmol/L)
Samples Application: Wicking action, end-fill
Samples Type: Fresh capillary whole blood
Primary site: Fingertip
Bluetooth Version: Bluetooth 4.1
Automatic Shutoff: 120 seconds after the last action
Weight Capacity: 180kg/396lb
Unit: kg/lb
Division: 5~100kg, 0.05kg/0.2lb; 100~180kg, 0.1kg/0.2lb
Power: 4*AAA carbon-zinc batteries.
Wireless: BLE 5.0
13 Essential body measurements
Multiple Users
High-sensitivity sensors and electrodes
Enjoy step-on technology, step on the scale to get quick results.
USA FDA510k (UL Medical)
Non-tipping over, Safe to step on the scale for measuring.
Designed for moderate –severe hearing loss
TWS style design
Qi Compatible wireless charge
Homietec Smart Health - We care Your health -
China
Email: bob@homietec.com / Message: +86 13616059395
All copyrights reserved - HOMIETEC SMART HEALTH - 2009 ~ 2023
A global trademark
Thank you for visiting our website, we apologize for the inconvenience caused by the fact that the website is under reconstruction. If you have any needs, such as product information or brochures, complaints and suggestions, etc., please send Email to bob@homietec.com.